Individual set points, differentials and time delays.
Cycling of compressors to avoid overloading one compressor.
Activate second compressor incase first compressor is not able to handle the load.
An internal 10sec time delay is provided to avoid simultaneous startups of compressors.
similar option for switching off as well to prevent an electrical surge.
Software keypad lock to avoid parameter tampering by bystanders.
Display | 7 Segment LED Display, 3 x 14.2mm (0.56”) |
Probe Inputs | NTC, Defrost (Coil) |
Relay Outputs | Compressor1 : 8(3)A Compressor2 : 8(3)A |
Power Supply | 230Vac Standard |
Temperature Range | -0.0°C to +50.0°C (Resolution 0.1°C, for SZ-7552-P) -40°C to +99°C (Resolution 1°C, for SZ-7562-P) |
Size | 75 x 34.5mm |
Mounting Type | Panel Mount, Panel Cutout : 71 x 29mm |
Application | 2 Independent cooling units with one temperature sensor |